• Review of indoor emission source models. Part 1. Overview
  • 2012-02-28
Indoor emission source models are mainly used as a component in indoor air quality (IAQ) modeling, which, in turn, is part of
exposure and risk modeling. They are also widely used to interpret the experimental data obtained from environmental chambers
and buildings. This paper compiles 52 indoor emission source models found in the literature. Together, they represent the
achievements that IAQ modelers have made in recent years. While most models have a certain degree of usefulness, genuine predictive
models are still few, and there is undoubtedly much room for improvement. This review consists of two parts. Part 1—this
paper—provides an overview of the 52 models, briefly discussing their validity, usefulness, limitations, and flaws (if any). Part 2
focuses on parameter estimation, a topic that is critically important to modelers but has